We use cookies to enhance the usability of our website. If you continue, we'll assume that you are happy to receive all cookies. More information. Don't show this again.
Antibody staining overlaps with GFP tagged protein
Figure description
Immunofluorescent staining of transgenic HeLa cells show antibody staining in cytoplasm, vesicles & nucleus but excluded from the nucleoli and GFP expression in nucleus but excluded from the nucleoli.
Antibody dilution
1:114
Standard validation
Supported
Supported
Figure description
Immunofluorescent staining of human cell line U-2 OS shows localization to nucleoplasm & cytosol.
Immunofluorescent staining of human cell line U-2 OS shows localization to nucleoplasm.
Antibody dilution
1:118
1:30
Literature conformity
The subcellular location is supported by literature.
The subcellular location is supported by literature.
IMMUNOHISTOCHEMISTRY
Antibody HPA003128
Antibody HPA004112
Antibody CAB000146
Standard validation
Supported
Supported
Supported
Figure description
Immunohistochemical staining of human colon shows strong nuclear and cytoplasmic positivity in glandular cells.
Immunohistochemical staining of human lymph node shows strong nuclear positivity in reaction center cells.
Immunohistochemical staining of human urinary bladder shows moderate nuclear positivity in urothelial cells.
Expression
RNA: detected in 37 tissues Protein: detected in 70 cell types
RNA: detected in 37 tissues Protein: detected in 69 cell types
RNA: detected in 37 tissues Protein: detected in 42 cell types
Retrieval
HIER pH6
HIER pH6
HIER pH6
Antibody dilution
1:100
1:15
1:200
Literature conformity
Consistent with extensive gene/protein characterization data.
Consistent with extensive gene/protein characterization data.
Consistent with extensive gene/protein characterization data.
RNA consistency
Mainly consistent with RNA expression data.
Mainly consistent with RNA expression data.
Mainly not consistent with RNA expression data.
WESTERN BLOT
Antibody HPA003128
Antibody HPA004112
Antibody CAB000146
Standard validation
Uncertain
Analysis performed using a standard panel of samples. Target too small/large to be analyzed with the present setup.
Uncertain
Analysis performed using a standard panel of samples. Target too small/large to be analyzed with the present setup.
Uncertain
Analysis performed using a standard panel of samples. Target too small/large to be analyzed with the present setup.
Figure description
Target mass (kDa)
264.2
264.2
264.2, 20.5, 14.7
Antibody dilution
1:250
1:250
1:500
PROTEIN ARRAY
Antibody HPA003128
Antibody HPA004112
Antibody CAB000146
Standard validation
Supported
Pass with single peak corresponding to interaction only with its own antigen.
Supported
Pass with single peak corresponding to interaction only with its own antigen.
Figure description
Antibody specificity analysis with protein arrays. Predicted and matching interactions are shown in green.
Antibody specificity analysis with protein arrays. Predicted and matching interactions are shown in green.