Immunofluorescent staining of human cell line U-2 OS shows localization to nucleoplasm, plasma membrane & cytosol.
Antibody dilution
1:59
Literature conformity
The subcellular location is supported by literature.
IMMUNOHISTOCHEMISTRY
Antibody HPA048244
Antibody CAB034200
Standard validation
Uncertain
Uncertain
Figure description
Immunohistochemical staining of human pancreas shows strong cytoplasmic positivity in exocrine glandular cells.
Immunohistochemical staining of human kidney shows strong cytoplasmic positivity in cells in tubules.
Expression
RNA: detected in 37 tissues Protein: detected in 24 cell types
RNA: detected in 37 tissues Protein: detected in 73 cell types
Retrieval
HIER pH6
HIER pH6
Antibody dilution
1:300
1:200
Literature conformity
No avaliable gene/protein characterization data.
No avaliable gene/protein characterization data.
RNA consistency
Mainly not consistent with RNA expression data.
Mainly consistent with RNA expression data.
WESTERN BLOT
Antibody HPA048244
Antibody CAB034200
Standard validation
Uncertain
Analysis performed using a standard panel of samples. Only bands not corresponding to the predicted size.
Uncertain
Analysis performed using a standard panel of samples. Single band differing more than +/-20% from predicted size in kDa and not supported by experimental and/or bioinformatic data.
Figure description
Lane 1: Marker [kDa] 250, 130, 95, 72, 55, 36, 28, 17, 11 Lane 2: RT4 Lane 3: U-251 MG Lane 4: Human Plasma Lane 5: Liver Lane 6: Tonsil
Target mass (kDa)
22.5, 9.7
22.5, 9.7, 6.7
Antibody dilution
1:300
1:500
PROTEIN ARRAY
Antibody HPA048244
Antibody CAB034200
Standard validation
Supported
Pass with single peak corresponding to interaction only with its own antigen.
Figure description
Antibody specificity analysis with protein arrays. Predicted and matching interactions are shown in green.