We use cookies to enhance the usability of our website. If you continue, we'll assume that you are happy to receive all cookies. More information. Don't show this again.
Immunofluorescent staining of human cell line A-431 shows localization to nucleoplasm & cytosol.
Immunofluorescent staining of human cell line A-431 shows localization to nuclear bodies & cytosol.
Antibody dilution
1:10
1:200
Literature conformity
The subcellular location is partly supported by literature or no literature is available.
The subcellular location is partly supported by literature or no literature is available.
IMMUNOHISTOCHEMISTRY
Antibody HPA012287
Antibody HPA053714
Standard validation
Uncertain
Uncertain
Figure description
Immunohistochemical staining of human cerebellum shows strong cytoplasmic positivity in Purkinje cells.
Immunohistochemical staining of human kidney shows strong cytoplasmic positivity in renal tubules.
Expression
RNA: detected in 32 tissues Protein: detected in 23 cell types
RNA: detected in 32 tissues Protein: detected in 17 cell types
Retrieval
HIER pH6
HIER pH6
Antibody dilution
1:15
1:1500
Literature conformity
Not consistent with gene/protein characterization data.
Not consistent with gene/protein characterization data.
RNA consistency
Not consistent with RNA expression data.
Not consistent with RNA expression data.
WESTERN BLOT
Antibody HPA012287
Antibody HPA053714
Standard validation
Uncertain
Analysis performed using a standard panel of samples. Single band differing more than +/-20% from predicted size in kDa and not supported by experimental and/or bioinformatic data.
Uncertain
Analysis performed using a standard panel of samples. No bands detected.
Figure description
Lane 1: Marker [kDa] 230, 130, 95, 72, 56, 36, 28, 17, 11 Lane 2: RT4 Lane 3: U-251 MG Lane 4: Human Plasma Lane 5: Liver Lane 6: Tonsil
Lane 1: Marker [kDa] 250, 130, 95, 72, 55, 36, 28, 17, 10 Lane 2: RT4 Lane 3: U-251 MG Lane 4: Human Plasma Lane 5: Liver Lane 6: Tonsil
Target mass (kDa)
48.2
48.2
Antibody dilution
1:250
1:1200
PROTEIN ARRAY
Antibody HPA012287
Antibody HPA053714
Standard validation
Supported
Pass with single peak corresponding to interaction only with its own antigen.
Supported
Pass with single peak corresponding to interaction only with its own antigen.
Figure description
Antibody specificity analysis with protein arrays. Predicted and matching interactions are shown in green.
Antibody specificity analysis with protein arrays. Predicted and matching interactions are shown in green.